GAO Yong-hui, CHEN Shu-ping, WANG Jun-ying, et al. Effects of Electroacupuncture of Different Acupoints Groups on Blood Pressure and Heart Rate Variability in Rats[J]. Acupuncture research, 2009, 34(1): 21-26.
DOI:
GAO Yong-hui, CHEN Shu-ping, WANG Jun-ying, et al. Effects of Electroacupuncture of Different Acupoints Groups on Blood Pressure and Heart Rate Variability in Rats[J]. Acupuncture research, 2009, 34(1): 21-26.DOI:
Effects of Electroacupuncture of Different Acupoints Groups on Blood Pressure and Heart Rate Variability in Rats
Objective To observe the effect of electroacupuncture(EA) of different acupoint groups on mean arterial pressure(MAP) and heart rate variability(HRV)in hypotension rats.Methods A total of 70 Wistar female rats were randomized into model
"Neiguan"(PC 6)-"Daling"(PC 7)
"Waiguan"(SJ 4)-"Yangchi"(SJ 5)
"Tianshu"(ST 25)-"Wailing"(ST 26)
"Dachangshu"(BL 25)-"Qihaishu"(BL 24)
"Baihui"(GV 20)-"Qianshencong"(EX-HN)
and"Guangming"(GB 37)-"Xuanzhong"(GB 39)groups
with 10 cases in each.Hypotension model was established by bleeding(2.5-3 ml) through carotid artery.Immediately after bleeding
EA(2/15 Hz
1 mA
30 min) was applied to the above-mentioned acupoints of the 6 EA groups.MAP and ECG were recorded
then HRV was analyzed by using software Chart 5.2.1.Results MAP declined significantly after bleeding.Compared with model group
MAP values of PC6-PC7 and GB37-GB39 groups increased significantly 15 min and 30 min after bleeding
and those of ST25-ST26 and GV20-EX-HN groups also increased apparently 30 min after bleeding(P<0.05).No marked effects were observed in EA of SJ4-SJ5 and BL25-BL24 groups(P>0.05).The effect of PC6-PC7 and GB37-GB39 groups was significantly superior to that of SJ4-SJ5
BL25-BL24 and GV20-EX-HN groups in elevating MAP 30 min after bleeding(P<0.05).Compared with model group
heart rate(HR) of PC6-PC7 group was increased significantly 15 min and 30 min after bleeding(P<0.05.).After bleeding
low frequency(LF)
LF/high frequency(HF) and very low frequency(VLF) increased apparently.Compared with model group
LF
LF/HF and VLF of PC6-PC7 and GB37-GB39 groups decreased significantly 30 min after bleeding(P<0.05)
suggesting a better balancing effect of EA of PC6-PC7 and GB37-GB39 on the activities of sympathetic and vagus nerves.Conclusion EA of different acupoint groups has its own relative specificity in regulating MAP and HR in the rat
and PC6-PC7 EA and GB37-GB39 EA have a better efficacy
which is closely associated with their effects in balancing activities of the autonomic nerve system.