A modified device for transcutaneous electrical auricular concha stimulation in rats
摘要
介绍一种改良的用于大鼠经皮耳甲电刺激的新型实验装置
通过电刺激大鼠的耳甲区
以探究刺激耳甲治疗疾病的作用机制。改良原有导线夹
使原有导线夹与铁片相连接
将吸附磁铁的铁片放置于待刺激耳甲区
另一块磁铁置于耳甲背侧的相应部位。改良后的导线夹既可牢固固定于大鼠耳甲区
又可解决导线夹长度不够、弹簧因反复夹持易松动等问题
此外还能避免原有导线夹的锯齿夹伤大鼠耳郭。
Abstract
In the present paper
we introduce a newly modified device named"transcutaneous electrical auricular concha stimulator(TEACS)"for rats. It concludes a main unit(power and control buttons)with newly designed specific output electrodes. Each of the output electrode is made up of two pieces of iron sheet containing magnet and can be firmly attached to the auricular concha and the corresponding site of dorsal auricle
respectively. The two iron sheets are separately connected to each of the output terminal of the main unit via two pieces of wire. This newly modified output electrode replaces the original wire clip
and solves the problems of easy loosening and easy injury of the original spring clip due to repeated usage