浏览全部资源
扫码关注微信
1. 福建省中医药研究院
2. 福建省中医药研究院,福州,350003
3. ,福州,350003
纸质出版日期:1993
移动端阅览
吴宝华, 胡翔龙, 许金森. 测试电压递增和递减时皮肤阻抗的变化[J]. 针刺研究, 1993,(2):104-107.
Wu Baohua Hu Xianglong Xu Jinsen. EFFECT OF INCREASE AND DECREASE OF MEASUREMENT VOLTAGE ON SKIN IMPEDANCE[J]. Acupuncture research, 1993, (2): 104-107.
本工作观察了测试电压递增和递减时皮肤低阻点和非低阻点阻抗的变化
观察对象为12名健康成人。结果表明
低阻点的阻抗随测试电压的递增和递减而出现相应的下降和上升的变化
但始终都处在低阻抗状态。而非低阻点在测试电压为10~50伏时
都处于高阻抗状态。只有当测试电压增高到65伏时
才有部分非低阻点的阻抗下降到接近低阻点的水平。但一旦测试电压降低
又随即恢复到高阻抗状态。二者的电学特性有显著的区别。低阻点和非低阻点之间的这种差异是自然存在的一种客观现象
并非实验误差所造成。
The skin impedance has been used as an index to plot out the meridian courses.In most of this kind of methods during measurement voltage was ne- cessary to deliver to the subject's skin.It is unknown whether increasing the measuring voltage can change non-low skin impedance points (non-LSIP) into low skin impedance points (LSIP).In order to clarify the problem
we made an investigation on the effect of increasing and decreasing the measuring voltage on skin impedance. Subjects under observation were 12 healthy volunteers.On the medial side of forearm two levels were selected for measurement.Four or twenty non- LISP were observed on each level.The measuring system worked on the basis of bielectrode method.The measurement and data processing were controlled by microcomputer.During measurement impedance of LSIP decreased correspo- ndingly with the increase of voltage and vice versa
but the value of impedance was not exceeded 100kΩ in spite of increasing or decreasing the voltage.That is
low impedance is the inherent characteristics of LSIP.On the contrary
the impedance of non-LSIP remained in higher than 600kΩ in most of cases during increasing voltage from 10 to 50v.As the voltage increased to 65v
the impe- dance in a part of non-LSIP decreased to such a low level as LSIP.However
thier impedance increased rapidly to high level again once the measuring voltage decreased.The above results reveal that the response of non-LSIPs and LSIPs were different from each other in nature.Increasing the voltage could not cha- nge a non-LSIP into LSIP.The difference between the two was not caused by the measurement errors
but really a biological phenonmenon.
0
浏览量
0
下载量
7
CNKI被引量
关联资源
相关文章
相关作者
相关机构